Upload\AgentStation.ini file

Section Common

In the [Common] section, the following keys can be configurated:

Key Description Values Default value
4900 Specifies the maximum number of uploads that can be executed in parallel. <1 ... 1024> 5
4902 Specifies what to do with files that are relevant for an Upload (Archive.zip and Backup.zip) after an upload has been completed. 0 or 1 1
H1ExclusiveUse Specifies whether the H1 driver is used exclusively. If PC-H1-PLC is selected as the access path, the upload may hang. One solution would be to allow only one H1 connection. Y/N N

Section ABBFreelance

In the [ABBFreelance] section, the following keys can be configurated:

Key Description Values Default value
5311 Specifies the full path to the ABB Freelance installation directory. Path Path to the registered COM server CBF.Application
5310 Specifies the ID with which the PC from which the upload is performed logs in to the resources. <1 ... 255> 21

Section AtlasCopcoTighteningSystems

In the [AtlasCopcoTighteningSystems] section, the following key can be configurated:

Key Description Values Default value
5011 Specifies the fully qualified path to the tool ttpf.exe from Atlas Copco. Path to tool No path

Section GEProficyMachineEdition

In the [GEProficyMachineEdition] section, the following key can be configurated:

Key Description Values Default value
36870 Specifies whether events/errors/warnings during the upload are logged in a file. The file is created under the name GE_PME_Upload.log in the temporary folder of octoplant. Y/N N

Section Kistler

In the [Kistler] section, the following key can be configurated:

Key Description Values Default value
36387 Specifies the location of the backup tool.exe from Kistler Path to tool {program directory of octoplant}\ThirdParty\Kistler

Section Lenze840DProtec

In the [Lenze840DProtec] section, the following key can be configurated:

Key Description Values Default value
5340 Specifies the full path to the installation directory of L-Force Engineer. Path No path

Section SickSensors

In the [SickSensors] section, the following key can be configurated:

Key Description Values Default value
5470 Specifies the fully qualified path to the directory containing the SDD files (device description files). Path ProgramData\SICK\SOPAS\jars\devices

Section SimaticS5

In the [SimaticS5] section, the following keys can be configurated:

Key Description Values Default value
5050 Specifies the network adapter to which the INAT H1 protocol is bound when uploading via H1. <0 ... 128> 0
5052 Specifies the number of the serial COM port to be used for the Upload via AS511 protocol. <1 ... 255> 1
5053 Specifies the path to the PLC-VCOM.EXE program from Process-Informatik.
The program is required for the upload via S5-LAN++. If the path has not been configured in the INI file, the octoplant system attempts to determine it automatically.
Path to PLCVCOM.EXE (without file name) No path

Section SimaticS7

In the [SimaticS7] section, the following keys can be configurated:

Key Description Values Default value
5090 Specifies the network adapter to which the INAT H1 protocol is bound when uploading via H1. 0 ... 128 0
5091 Specifies the access point for SIMATIC NET. The access point must first be configured in SIMATIC NET. Name of access point S7ONLINE
5092 Specifies whether F-Blocks from the controller program should also be copied when the program is copied to a PC via the UserClient. If the F-Blocks are not copied, a message is displayed. Y/N N