Upload\AgentStation.ini file
Common
In the [Common] section, the following keys can be configured:
| Key | Description | Values | Default value |
|---|---|---|---|
| 4900 | Specifies the maximum number of uploads that can run simultaneously across all upload types. This key can also be set in the corresponding section of the respective upload type to apply a stricter limit for that specific type. This type-specific value must be less than or equal to the value under [Common] and must never exceed it. | <1 ... 1024> | 5 |
| 4902 | Specifies what to do with files that are relevant for an Upload (Archive.zip and Backup.zip) after an upload has been completed. | 0 or 1 | 1 |
| H1ExclusiveUse | Specifies whether the H1 driver is used exclusively. If PC-H1-PLC is selected as the access path, the upload may hang. One solution would be to allow only one H1 connection. | Y/N | N |
ABBFreelance
In the [ABBFreelance] section, the following keys can be configured:
| Key | Description | Values | Default value |
|---|---|---|---|
| 5311 | Specifies the full path to the ABB Freelance installation directory. | Path | Path to the registered COM server CBF.Application |
| 5310 | Specifies the ID used by the PC performing the upload to log in to the resources. | <1 ... 255> | 21 |
AtlasCopcoTighteningSystems
In the [AtlasCopcoTighteningSystems] section, the following key can be configured:
| Key | Description | Values | Default value |
|---|---|---|---|
| 5011 | Specifies the fully qualified path to the tool ttpf.exe from Atlas Copco. | Path to tool | No path |
GEProficyMachineEdition
In the [GEProficyMachineEdition] section, the following key can be configured:
| Key | Description | Values | Default value |
|---|---|---|---|
| 36870 | Specifies whether events/errors/warnings during the upload are logged in a file. The file is created under the name GE_PME_Upload.log in the temporary folder of Octoplant. | Y/N | N |
Kistler
In the [Kistler] section, the following key can be configured:
| Key | Description | Values | Default value |
|---|---|---|---|
| 36387 | Specifies the location of the backup tool.exe from Kistler | Path to tool | {program directory of Octoplant}\ThirdParty\Kistler |
Lenze840DProtec
In the [Lenze840DProtec] section, the following key can be configured:
| Key | Description | Values | Default value |
|---|---|---|---|
| 5340 | Specifies the full path to the installation directory of L-Force Engineer. | Path | No path |
SickSensors
In the [SickSensors] section, the following key can be configured:
| Key | Description | Values | Default value |
|---|---|---|---|
| 5470 | Specifies the fully qualified path to the directory containing the SDD files (device description files). | Path | ProgramData\SICK\SOPAS\jars\devices |
SimaticS5
In the [SimaticS5] section, the following keys can be configured:
| Key | Description | Values | Default value |
|---|---|---|---|
| 5050 | Specifies the network adapter to which the INAT H1 protocol is bound when uploading via H1. | <0 ... 128> | 0 |
| 5052 | Specifies the number of the serial COM port to be used for the Upload via AS511 protocol. | <1 ... 255> | 1 |
| 5053 | Specifies the path to the PLC-VCOM.EXE program from Process-Informatik. The program is required for the upload via S5-LAN++. If the path has not been configured in the INI file, the Octoplant system attempts to determine it automatically. | Path to PLCVCOM.EXE (without file name) | No path |
SimaticS7
In the [SimaticS7] section, the following keys can be configured:
| Key | Description | Values | Default value |
|---|---|---|---|
| 5090 | Specifies the network adapter to which the INAT H1 protocol is bound when uploading via H1. | 0 ... 128 | 0 |
| 5091 | Specifies the access point for SIMATIC NET. The access point must first be configured in SIMATIC NET. | Name of access point | S7ONLINE |
| 5092 | Specifies whether F-Blocks from the controller program should also be copied when the program is copied to a PC via the UserClient. If the F-Blocks are not copied, a message is displayed. | Y/N | N |