CODESYS
octoplant supports the management of CODESYS projects and enables the cyclical monitoring of devices that have been configured with this development environment.
Device Support Level
Key features
Other features
- Asset inventory support
Workflow
System requirements
CODESYS | V 2.1 | V 2.3 | V 3.5 SP 9 | V 3.5 SP 10 - SP 15 | V 3.5 SP 16-SP 18 |
---|---|---|---|---|---|
octoplant 101 | ✓ | ✓ | ✓ | ✓ | |
octoplant 101.1.0 | ✓ | ✓ | ✓ | ✓ | ✓ |
Other system requirements
- To integrate and compare projects, a compatible version of the editor must be installed on the same computer on which the server or an agent is running.
- V2.* and V3.* projects may not be integrated simultaneously in one CODESYS component.
- Encrypted CODESYS projects cannot be integrated.
- The upload is carried out using the CODESYS PLC Handler.
The correct editor is automatically determined for the listed manufacturers with the following search sequence (*CODESYS V2.X only):
- CODESYS
- SoMachine (CODESYS V3)
- CPS21 (Bosch)*
- TwinCat (Beckhoff)** TwinCAT V3 contains its own editor.
- MOVITOOLS® MotionStudio (SEW-EURODRIVE)*
- ELAU (Schneider Electric)
- Indralogic (Bosch Rexroth)*
- EATON
The search sequence can be changed using a script.
Notes
CODESYS V2.X:
* For technical reasons, project information and device properties are not recognized.
CODESYS V3.X:
- Visualization and user administration are not supported.
Related topics
To get the basic workflow for intergrating the device, open General workflow.
Device-specific settings for this device, such as job configuration, can be found on the following pages: