Skip to content

Backup requirements

An essential prerequisite for backing up a MOTOMAN-NX100 is that the machine can be accessed via an FTP server:

  • The FTP function must be activated on the NX100. General parameters: FD***=1
  • FTP server setting: CommandRemote must be activated. General parameters: RS001=1 or the order on the programming device:
    1. Management Mode
    2. IO
    3. Pseudo Input Signal
    4. Command Remote=on
  • It may be necessary to set the RS007 parameter to the value 2. General parameters: RS007 =2

Info

This option extends the functionalities of the read-only mode of the data transfer function. When using the Command Remote mode (PSEUDO INPUT SIGNAL set to CMD REMOTE SEL and programming device switched to REMOTE), this setting should not be necessary.