Backup requirements
An essential prerequisite for performing a backup of a MOTOMAN-NX100 is that the FTP server can access the machine:
- Activate the FTP function on the NX100. General parameters: FD***=1
-
Activate the FTP server setting: Command Remote. General parameters: RS001=1 or the following order on the programming device:
- Management Mode
- IO
- Pseudo Input Signal
- Command Remote=on
This option is only available on devices with version NS3.00.00A(*)-00 or higher).
- If necessary, set the RS007 parameter to the value 2. General parameters: RS007 =2 This option extends the functionalities of the read-only mode of the data transfer function. When using the Command Remote mode (PSEUDO INPUT SIGNAL set to CMD REMOTE SEL and programming device switched to REMOTE), you don´t need to set the parameters.