Skip to content

Configuring jobs for Omron Sysmac Studio

Prerequisites for performing a backup

  • Clear the Start monitoring safety application checkbox. This setting is located in Sysmac Studio under Option > Safety > Monitoring safety applications > Start monitoring safety application. If this checkbox is selected, the upload will fail because a dialog appears in the editor that must be closed manually during the upload process.
  • Ensure the C:\Program Files\OMRON\Sysmac Studio\SysmacStudio.exe.config file contains the following line: <add key ="WcfServiceEnable" value="True" /> The value has to be set to True.

Procedure

  1. Create a job for the Omron Sysmac Studio upload type.
  2. Go to the Omron Sysmac Studio settings section.
  3. If the component contains several project files (.pro), select the desired project from the dropdown menu.