Skip to content

Cognex DataMan Scanner

octoplant supports the management of Cognex scanners (stationary and portable versions) and enables the automatic creation of backups and the cyclical monitoring of the devices.

DataMan: This program performs the Upload for Cognex scanners, which can be edited with the publicly available Application Programming Interface DataMan SDK.

Device Support Level

Figure: Device Support Level Cognex DataMan Scanner

Key features

Figure: Cognex DataMan Scanner Key features

Workflow

Figure: Workflow Cognex DataMan Scanner

Supported versions

Device Type octoplant 101 octoplant 101.4
Handheld Scanner
DM8600, DM8050/DM8050X Series
Firmware from version 5.4.4
Handheld Scanner
DM8072 Series
Firmware from version 5.7
Handheld Scanner
DM8700 Series
Firmware from version 6.2.7_sr2
Fixed-Mount Scanner*
DM70, DM150, DM260, DM300, DM360, DM370, DM470
Firmware from version 5.7
Fixed-Mount Scanner
DM280 Series
Firmware from version 6.3.6

* The DM100 and DM200 series are not supported.

Requirements

  • To carry out uploads, the .NET Framework 4.0 must be installed.
  • Supported connection paths: TCP/IP and COM. The DataMan Editor is required when uploading via the serial interface.