Configuring jobs for KISTLER DMF-P and maXYmos process monitors

Prerequisite

To upload data from KISTLER DMF-P and maXYmos process monitors, the services must run under a specific user account with membership in the Administrators group. The upload will fail if the VDog MasterService, VDog UploadAgent, or VDog CompareAgent applications are run under the Local System account.

Procedure

  1. Create a job with the Kistler upload type.
  2. Go to the Kistler settings section.
  3. In the Device field, enter the IP address or the name of the device.
  4. In the User and Password fields, enter your credentials for network access.
  5. From the Type dropdown menu, select the device class DMF-P *** * or maXYmosTL/NC**.
  6. You can define the following settings for the DMF-P * device class:

    1. From the Sensor X and Sensor Y dropdown menus, select the appropriate sensors for your device.
    2. From the Display setting dropdown menu, select Standard or Special (notebook 16/9).
    3. From the Fieldbus dropdown menu, select the correct network for accessing the device.
    4. Select or clear the Create delivery note for the backup checkbox and enter a comment for the delivery note if necessary.
  7. In the Port field, adjust the port for the maXYmosTL/NC device class. Port 22 is set by default.