Configuring jobs for PHOENIX CONTACT MGUARD routers
-
Create a job with the Switches upload type.
-
In the Device field under Switch settings, enter the IP address or the name of the device.
- In the User and Password fields, enter the credentials for the user account used to access the device.
- From the Type dropdown menu, select mGuard.
- In the Port field, enter the outgoing port used to establish the connection to the device. The default value is 23 for TFTP and 22 for SSH.