Configuring jobs for Schneider EcoStruxure Machine Expert

Jobs for the backup of Schneider EcoStruxure Machine Expert projects are created using CODESYS V3.

  1. Create a job with the CODESYS upload type.
  2. Go to the CODESYS settings section.

    Figure: Job configuration, CODESYS settings section

  3. If the component contains several projects, select the desired project from the dropdown menu.

  4. From the Interface Type dropdown menu, select one of the Gateway V3 or ARTI V3 entries. Alternatively, you can also enter "interfacetype=..." in the Access parameters input field.
  5. In the Gateway IP, Gateway port and Gateway password fields, enter the connection data of the Gateway. If no port is specified here and in the Access parameters field, the default port 1217 is used.
  6. In the Device, PLC IP and PLC port fields, enter the connection data of the device. If no port is specified here or in the Access parameters field, the default port 11740 is used.
  7. In the User account and User password fields, enter the credentials for the user account used to access the device.
  8. The access data entered in the fields above can also be specified in the Access parameters field.

    Info

    If data is entered in both the individual fields and in the Access parameters field, the values in the Access parameters take precedence for backward compatibility.

    Make sure the following parameters are correctly specified:

    • value0={IP address of the PLC}
    • value1={Port number}