Skip to content

Comparing projects

  • Unit data is compared with the VarData interpreter application from MOVITOOLS® MotionStudio.
  • Units that are only integrated via networks are not taken into account in the parameterization comparison.
  • In addition to the parameters that are excluded from the comparison by the VarData interpreter, octoplant also excludes the following parameters:

    • 8455.0: PA1 setpoint
    • 8456.0: PA2 setpoint
    • 8457.0: PA3 setpoint
    • 8458.0: PE1 actual value
    • 8459.0: PE2 actual value
    • 8460.0: PE3 actual value
    • 8705.0: Sampling time
    • 8706.0: Scope tracking cycles
    • 8707.0: Scope trigger source
    • 8708.0: Scope rising edge
    • 8717.0: Scope debug address 1
    • 8718.0: Scope debug address 2
    • 8719.0: Scope debug address 3
    • 8720.0: Scope debug address 4
    • 9095.0: Analog trigger mask
    • 9081.0: Debug address 5
    • 9082.0: Debug address 6
    • 9083.0: Debug address 7
    • 9084.0: Debug address 8
    • 9085.0: Debug index 1 and 2
    • 9086.0: Debug index 3 and 4
    • 9087.0: Debug index 5 and 6
    • 9088.0: Debug index 7 and 8
    • 9089.0: Trigger behavior
    • 9090.0: Trigger selection
    • 9091.0: Trigger source
    • 9092.0: Trigger mode
    • 9093.0: Analog trigger level
    • 9094.0: Analog trigger hysteresis