Skip to content

Bug fixes: 7.5.0

The following points have been fixed in this update:

Error with devices/functionality of the applications

  • Disk Image: Job reports error: directory cannot be created
  • GE Proficy ME: Error in comparison: instructions are displayed incorrectly / upload of individual targets / Redundancy PLCs were not supported (comparison)
  • RSLogix 5000: Possible crash during comparison backup ↔ version / check during upload if an editor is active, is not correct
  • Schneider Citect SCADA: Possible pseudo differences
  • Siemens S5: Function Editor Open no longer available after update with versiondog 7.0.X
  • Siemens S7: Possible error when versioning a component
  • Siemens Simotion: comparison may not show all differences
  • Siemens TIA Portal: Devices in groups cannot be expanded in the project tree / groups with subgroups are not displayed correctly in the difference tree / Possible pseudo differences
  • Siemens SIMATIC WinCC: Possible crash when versioning without editor / error message added if editor is missing.
  • Siemens SIMATIC WinCC Flexible: Possible error when versioning a component
  • Wonderware InTouch: Possible SQL error when checking in a project
  • versiondog UserClient: UserClient crashes sporadically when changing the lock status / incorrect progress display during upload and comparison in the UserClient / Under certain circumstances, a job is shown twice in the daily report

Error due to the unicode conversion

  • Various database migration errors due to corrupt databases or unexpected encoding of the content
  • VDog MasterService: License check: Special characters in the XML lead to errors
  • Database migration aborts if the name of the ClientArchive contains spaces
  • Special characters prevent Check-In of Schneider Concept project
  • SmartUpdate: if a file with non-ASCII characters (e.g. Delete.txt) in the Setup share directory leads to errors
  • Cognex In-Sight job cannot be saved under certain circumstances
  • Projects with special characters in the path and dBase database cannot be opened
  • Siemens SINUMERIK 840D Operate: versioning may not be possible
  • Users with @ in user name causes problems during import
  • Database migration to UTF-8 is not robust against virus scanners or other external influences
  • Siemens S7: Possible F-Block errors with update to 7.0.1
  • Siemens S7: Possible pseudo differences
  • Display problem with umlauts in the event display of job results
  • Possible SQL error when sending daily emails
  • Create a base version and check in: process may take longer since version 7.0.X
  • Incorrect display of Tags added with versiondog AutoCheckIn
  • Creation of a support package may fail with an error message