Configuring jobs for Cognex In-Sight SDK
Prerequisites
To ensure that differences are not displayed each time the job is executed, Cognex In-Sight jobs (files) must first be saved by the corresponding image processing sensor.
To do this, proceed as follows:
- Load the Cognex In-Sight job (file) onto the sensor.
-
In the System menu, select Save.
-
In the Save dialog, select the sensors to be saved.
-
The files of the selected sensors are now backed up. Copy the files to the component and check in the new version.
Procedure
- Crate a job with the Cognex Sensors upload type.
- Go to the Cognex Sensors settings section:
- From the Type dropdown menu, select the In-Sight (SDK) device class.
- Enter the IP address or the name of the device in the Device field.
- In the User and Password fields, enter the credentials for the user account used to access the device.
- In the Save current job as field, enter a file name.
- In the Exclude files/directories field, you can specify files or directories to be excluded from the job configuration. Use a semicolon (;) to separate multiple entries. The characters (*) and (?) can be used as wildcards.
The backup created is identical to the project created by Cognex In-Sight. The result is suitable for a detailed comparison, further processing and disaster recovery.