Upload & Comparison¶
Depending on the job configuration, the following files are backed up during job execution:
Contents | Memory | Comparison | Name |
---|---|---|---|
Copy data for disaster recovery | |||
Complete image of the SRAM | SRAM | No | SRAM_BAK.001 |
PMC Sequence program | FROM | Yes (SmartCompare) | PMCx, x=1,2,3,4,5,S |
PMC Message File | FROM | Yes (binary) | MxPMCMSG, x=1,2,3,4,5 |
I/O configuration data | FROM | Yes (binary) | IOCONF |
C language executer application data | FROM | Yes (binary) | CEX_nnM |
C language executer user data | FROM | Yes (binary) | CEXnxxxx |
Macro executer application data | FROM | Yes (binary) | PDnnxxxx |
FANUC Picture project (compiled) | FROM | Yes (binary) | FPF 2.0M or FPF0 |
NC programs in binary form | FROM | Yes (binary) | ATA PROG |
Maintenance data (spare part numbers, software packages installed on the CNC) | FROM | Yes (binary) | MAINTINF |
Other files | FROM | Yes (binary) | |
Copy PMC data | |||
PMC parameters | SRAM | Yes (ASCII) | PMCx_PRM.TXT, x=1,2,3,4,5,S |
PMC Sequence program | FROM | Yes (SmartCompare) | PMCx, x=1,2,3,4,5,S |
PMC Message File | FROM | Yes (binary) | MxPMCMSG, x=1,2,3,4,5 |
I/O configuration data | FROM | Yes (binary) | IOCONF |
Copy CNC data | |||
NC programs | SRAM | Yes (ASCII) | \PROGRAM_MEMORY\CNC_MEM\MTB1\ABC |
Tool offset data | SRAM | No | TOOLOFST.TXT |
CNC parameters | SRAM | Yes (ASCII) | CNC-PARA.TXT |
Pitch error compensation data | SRAM | No | PITCH.TXT |
Custom macro variables | SRAM | Yes (ASCII) | MACRO.TXT |
Work zero offset data | SRAM | Yes (ASCII) | EXT_WKZ.TXT |
Operation history data | SRAM | No | OPRT_HIS.TXT |
Rotary table dynamic fixture offset | SRAM | Yes (ASCII) | FIXTURE.TXT |
Copy all user data from the FROM | |||
Other files (also includes the SRAM backups (automatic data backup)) | FROM | Yes (binary) |
Info
-
Not all of these files are available/retrievable on some of the supported devices. Non-retrievable files can only be backed up manually due to the machine configuration.
-
If a PMC program has been changed on the controller without a backup being stored in the FROM, a warning will be displayed when uploading.
-
During comparison, the path stored in the LAD/PMC files (PMCx, x=1,2,3,4,5,S) is used instead of the file name for assignment.
-
Only the LAD files are compared when comparing versions.